USER.DOC PC/370 User Documentation
Copyright 1987 Donald S. Higgins
Don Higgins
6365 - 32 Avenue North
St. Petersburg, Florida 33710
E-mail CompuServe 73047,1113
PC/370 users:
This is the user documentation for the PC/370 cross assembler,
linkage editor, and emulator for 370 assembly language users.
The PC/370 package provides the capability to assemble, link,
and execute IBM 370 assembler programs on any 80x86 MSDOS 2.0+ micro
computer such as the IBM PC, XT, AT, PS/2, Compaq, etc.
Chapter table of contents:
1. M370.COM macro preprocessor
2. A370.EXE cross 370 assembler
3. L370.EXE cross 370 linkage editor
4. E370R42.EXE run time 370 emulator
5. Technical hardware and software specifications
6. ASSIST extended instructions for student use
7. DEBUG interactive debugging facility
8. Floating point instructions and scientific subroutines
9. XA extended architecture instructions
10. System subroutine library
11. COBOL call interface
12. Reference publications
*********
Chapter 1. M370.COM macro preprocessor
*********
The M370 macro preprocessor has the following command format:
A>M370 file
where file is the name of a source macro program file which has the
suffix (.MLC). The source file must be in ASCII text format with
each line terminated by a line feed character. The only output from
this program is a source basic assembler file with expanded macro
statements. The suffix of the output file is (.ALC).
Any number of macros can be used by M370 input files and must be
defined in individual source macro files with the file name equal to
the macro name and a suffix of (.MAC). These macros must be placed on
the default drive for access by M370. For more speed, these files may
be moved to RAM disk.
*********
Chapter 2. A370.EXE cross 370 assembler
*********
The A370 assembler has the following command format:
A>A370 file/options
where file is the name of a source program file which has the
suffix (.ALC). The source file must be in ASCII text
format with each line terminated by a line feed character.
Any number of editors including SEE can be used to create ALC files.
An optional drive and path may be specified such as B:\dir\file.
The options which can be specified are as follows:
A - alignment option. Default is on.
C - object code option. Default is on.
L - produce listing file (.PRN). Default is none.
T - trace assembler execution. Default is off.
X - produce symbol and literal cross reference. Default is none.
If an option is on by default, specifying it will turn it off.
For example:
A>A370 B:DEMOPNUM/LX
will read the source file B:DEMOPNUM.ALC and produce the object
code file B:DEMOPNUM.OBJ and the listing file B:DEMOPNUM.PRN.
The A370 assembler conforms to the OS/VS IBM 370 Assembly
Language as defined in the IBM manual GC33-4010 with the
following limitations:
1. No continuation lines.
2. Maximum control sections and dummy sections is 255.
3. Macros and system variable symbols are not supported (see M370).
4. OPSYN statement not supported.
5. EQU third operand (type attribute) not supported.
6. Scale, exponent, and bit length data modifiers not supported.
Extended features include the following:
1. Data constant types F and H may use arithmetic expressions.
2. Extended ASSIST instruction set including XREAD, XPRNT,
XDECI, XDECO, AND XDUMP as defined in the book Assembler
Language with ASSIST by Ross A. Overbeek. Also 2 more
instructions XFILI and XFILO are added to allow changing
default ASSIST input and output files at execution time.
3. ASCII character strings may be defining by using double
quotes instead of single quotes in DC and self defining
character constants.
*********
Chapter 3. L370.EXE cross 370 linage editor
*********
The L370 linkage editor has the following command format:
A>L370 file/options
where file is the name of an A370 object code file (.OBJ) and
may specify a specific drive. The options supported by the
linkage editor are as follows:
B - create VS COBOL callable subroutine file (type .BIN).
D - set debug mode for emulator. Default is off. When option D
is on, interactive debug is entered at beginning of each
COM or BIN file execution.
G - load and execute with no file output. Default is off.
I - turn off all interrupts from keyboard.
L - list CSECT addresses and lengths. Default is off.
M - create 370 code module without COM prefix code.
O - dump input object code records in hex. Default is off.
P - force floating point option off even if 80x87 installed.
X - cross reference of external symbols. Default is off.
U - allow unresolved external references
For example:
A>L370 B:DEMOPNUM/LX
will read the object code file B:DEMOPNUM.OBJ and produce the binary
command file B:DEMOPNUM.COM, and the listing and cross-reference file
B:DEMOPNUM.LST. Note that since DEMOPNUM calls the external
subroutine PET, the subroutine library L370.LIB must be available.
The binary command file B:DEMOPNUM.COM may be directly executed by the
MSDOS command:
A>B:DEMOPNUM
When the above command is executed, the program will load at X'0200'
and the fetch routine linked with the program will load the
emulator E370.EXE in high memory and transfer control to it.
The linkage editor uses two concatenated subroutine library
files. The first file is named file.LIB and may contain
any number of A370 subroutine object modules which are called by the
modules in file.obj. This file is optional and only called modules
are included. The second file is named L370.LIB and may contain any
number of A370 subroutine object modules which are commonly used by
multiple programs. An L370.OBJ file is included with the PC/370
package and contains sample time and date routines. The MS-DOS COPY
command with option /B may be used to concatenate A370 object modules
in either library file. Note module references must be resolved in
one sequential pass of library so backward module references may cause
unresolved entry.
The linkage editor listing file (.LST) shows relative entry point
and segment lengths and optional cross reference by segment. The
last line of the listing contains ENT/LNG which is the 370 relative
entry point of the module and the length of the entire module.
*********
Chapter 4. E370R42.EXE run time 370 native machine code emulator
*********
The emulator is transparent to the user when using A370 and L370 to
create MSDOS command files. The emulator is dynamically executed by
the 80x86 COM file prefix generated by L370. The 370 machine code
starts at X'210' from the beginning of the COM file. The origin of
the 370 virtual address space for a COM program starts at X'10' from
the beginning of the COM file. The execution of the 370 machine code
will start at the specified relative start address plus hex 200 with
that absolute address in register 15. Register 1 will point to
standard MVS parameter list address at location X'80' with EBCDIC text
passed from MS-DOS command line. Register 13 will point to standard
save area in ASCB and register 14 points to return to detach
instruction in ASCB to exit to MS-DOS. If a program check occurs, the
interactive debug facility will be invoked and will initially display
the general registers and the program status word at the time of the
interruption. See DOC\SYSTEM.DOC SPIE supervisor call for facility to
handle program checks. Also see MAC\MVS.MLC for example of how to run
programs in problem state with your own supervisor shell.
A new facility with PC/370 release 4 is the ability to make the
emulator resident by simply executing it directly. The resident
emulator reserves about 50k for code and uses an 80x86 hardware
interrupt to transfer control when needed at execution time. To
remove the current resident emulator, simply execute it directly
again. Release 4.0 and 4.1 used interrupt hex DC. Release 4.2 uses
hex 60 within the Micro Focus Extended Memory (XM) real interrupt
handler range of hex 60-6F. See DOC\PTF.DOC for pathc to change
interrupt in case it conflicts with another user installed software
package.
With release 4.1 a new system queue area (SQA) memory option has been
added to define a memory which can be shared by all COBOL subroutines
and which is allocated in the resident emulator address space. The
size of the SQA is specified by a single hex parm when making the
emulator resident. The size is in hex paragraphs and the default is
10 or 256 bytes. For example, the following command would make the
emulator resident with an 8k byte SQA:
C>E370R42 200
With the SQA facility, COBOL assembler subroutines can issue standard
file I/O with dynamic buffers allocate from SQA. See BAT\RUNCBL.BAT
for demo.
With release 4.2, PC/370 supports Micro Focus COBOL/2 assembler
subroutine calles in normal MS-DOS mode or in extended memory XM mode.
In both cases the emulator must be resident before starting the COBOL
program via workbench or run time executive with or without XM. In
XM mode, the emulator still runs in real mode after requesting XM to
mode the called subroutine code (BIN file) and the argument data
segments to base memory area for access in V=R real mode. This
creates the XM restriction that there must be sufficient base memory
for called BIN file and data segment at the time of the call. Also,
the emulator must not attempt to access memory beyond end of BIN or
data segments in real memory. The emulator can use SQA in XM mode.
See BAT\RUNCBL.BAT for demo of XM mode subroutines (requires XM.EXE
and RUN.EXE from Micro Focus).
There are five distinctly different ways to execute the E370 emulator:
1. Direct execution to make it resident if not currently resident.
2. Direct execution again to remove current resident copy. If
another software package is using interrupt, an error message
will display. See DOC\PTF.DOC to change interrupt number.
3. Execution of a 370 COM module without E370 resident causes
dynamic loading of E370 in high 64k of MS-DOS memory to support
execution of 370 code in the COM module.
4. Execution of a 370 COM module with E370 module resident causes
execution of resident copy via cross memory interrupt facility.
5. Execution of a 370 BIN module from within Micro Focus COBOL run
time environment causes execution of resident copy via cross
memory interrupt facility. In XM mode, a protected interface
routine in the emulator is called directly by the BIN module
which in turn issues interrupt to execute emulator in real mode.
*********
Chapter 5. Technical specifications
*********
1. A370.EXE requires 256k memory to execute and can handle source
programs with over 1000 labels.
2. L370.EXE requires 256k memory and can handle load modules up to
50k bytes long.
3. E370R42.EXE requires 50k plus SQA which includes the emulator,
and the extended SVC support functions, and interactive debug.
A production only copy of the emulator named E370P42.EXE is
included which only requires 40k but does not include
interactive debug facility or the ASSIST extended instructions.
This version saves resident base memory, but should only be
used for fully tested programs or programs with their own
program check handlers for error recovery.
4. E370R42 supports all the non-supervisor state IBM 370
instructions as defined in the IBM/370 XA Principals
of Operation manual SA22-7085 except the conditional
swapping feature instructions. Short, long, and extended
floating point instructions are supported provided 80x87
is installed.
5. The minimum configuration for PC/370 is as follows:
a. 80x86 processor. XM only supported on 80286/80386.
b. 256k RAM memory which allows execution of 370 program in
128k virtual address space. Maximum virtual address space
is about 512k on 640k machine.
c. 1 floppy disk drive.
d. 80x87 only required for floating point instructions.
6. A benchmark program consisting of calculating the first
100 prime numbers was run in interpretive BASIC using
16 bit integer arithmetic. It took 67 seconds on a
4.77 MHZ 8086 system. The same program was rewritten in
370 assembler using 32 bit fixed point arithmetic. It
took 25 seconds to execute on the same system. This
benchmark program is included as a demo called DEMOPNUM.ALC.
The demo may be run with the following commands:
A>A370 DEMO\DEMOPNUM/LX (create DEMOPNUM.OBJ)
A>L370 DEMO\DEMOPNUM/LX (create DEMOPNUM.COM)
A>DEMO\DEMOPNUM
7. The following error messages are supported:
A370/L370
E01 - DUPLICATE LABEL
E02 - INVALID LABEL
E03 - SYMBOL TABLE FULL
E04 - INVALID OPERATION CODE
E05 - UNDEFINED OPERATION CODE
E06 - UNDEFINED LABEL
E07 - INVALID OPERAND
E08 - MEMORY FULL
E09 - EXPRESSION INVALID
E10 - SELF DEFINING TERM INVALID
E11 - ARITHMETIC OVERFLOW IN EXPRESSION
E12 - TOO MANY EXTERNAL SYMBOLS
E13 - NO BASE REGISTER AVAILABLE
E14 - LENGTH ERROR
E15 - OPERAND ERROR
E16 - DATA CONSTANT DUPLICATION FACTOR ERROR
E17 - DATA CONSTANT TYPE ERROR
E18 - DATA CONSTANT LENGTH ERROR
E19 - DATA CONSTANT DATA ERROR
E20 - START SEQUENCE ERROR
E21 - LTORG SEQUENCE ERROR
E22 - LOCATION COUNTER ERROR BETWEEN PASS 1 AND 2
8. IOS LOGICAL ACCESS METHOD USED BY A370, L370, AND E370
IOS001 - NO DISK SPACE
IOS001 - FILE NOT FOUND
IOS001 - NO BUFFER SPACE
IOS001 - OPEN FAILED
IOS002 - CLOSE FAILED
IOS003 - READING UNWRITTEN DATA
IOS003 - INVALID REQUEST
IOS004 - ERROR IN EXTENDING FILE
IOS004 - END OF DISK DATA AREA
IOS004 - NO MORE DIRECTORY SPACE
IOS004 - INVALID REQUEST
IOS005 - INVALID RECORD TYPE
IOS005 - INVALID RECORD LENGTH
IOS006 - INVALID RECORD TYPE
IOS006 - INVALID RECORD LENGTH
IOS007 - DELETE FAILED
*********
Chapter 6. ASSIST extended instructions for student use
*********
A. Overview
The book, "Assembler Language With ASSIST", by Ross A. Overbeek
and W. E. Singletary published by Science Research Associates,
Inc. in 1976 describes a set of 370 extended instructions to
greatly simplify input and output for students learning to write
370 assembler programs. A new book with also covers ASSIST is,
"IBM 370 Assembly Language with ASSIST, Structured Concepts, and
Advanced Topics", Charles J. Kacmar, Prentice Hall, September
1987, ISBN 0-13-455742-5.
PC/370 implements these instructions to allow students to
code, assemble, and execute ASSIST 370 programs on any 80x86 MS-
DOS based micro-computer rather than having to use an IBM 370
mainframe. This was the original objective for which PC/370 was
developed back in 1981. The first students to use PC/370 with
ASSIST were volunteers at the University of South Florida,
College of Engineering. The students used a CP/M based Z80
micro-computer with the original version of PC/370 instead of
the IBM 3033 mainframe ASSIST system accessed via RJE using
keypunched card decks.
B. ASSIST extended instructions
1. XFILI =C'filename'
This extended instruction redirects input source for XREAD.
If open, the current input source file is closed. The new
filename can be any standard MS-DOS path/filename ending
with suffix .xxx or a zero byte. If the filename is CON:
then the input source is the console with a ? prompt. To
set the ASSIST end of file condition code for XREAD from the
console, use the escape (ESC) key. See DEMOAST3.ALC for
demo of redirection.
2. XFILO =C'filename'
This extended instruction redirects the output from XPRNT.
If open, the current output file is closed. The new file
name can be any standard MS-DOS path/filename ending with
suffix .xxx or a zero byte. If the filename is CON: then
the output from XPRNT is directed to the console. The first
byte which is printer control code is also printed on
console.
3. XREAD area [,length]
Read record into area with default length of 80 padded with
blanks. If the input is coming from console, the first
carriage return defines end of record, and single ESC
character defines end of file. Note ASCII characters from
console or file are automatically translated to EBCDIC in
record area. Condition code set as follows:
0 - read successful
1 - end of file
Default input source is file named ASSIST.DAT. If the file
is not found, the input and output source is switched to
console.
4. XPRNT area [,length]
Print record from area with default length of 132. Trailing
blanks are stripped off. The first character is used as
standard ASCII print control character:
' ' - space means skip one line
'/' - slash means skip two lines
'1' - one means skip a page
'+' - means skip no lines
'-' - dash means skip three lines
Output to console includes print control character. Default
output is to file named ASSIST.PRN which is also used by
interactive debug X logging command and XDUMP.
5. XDECI reg,area
Read ASCII integer number from area and store into register.
Leading plus or minus signs may be present. Condition code
is set as follows:
0 - number is zero
1 - number less than zero
2 - number is greater than zero
3 - no number found in area
Register 1 is set to address of first character after number
read.
6. XDECO reg,area
Convert binary integer number in register to 12 character
display field with numeric value including sign.
7. XDUMP [area start, area end]
Dump general purpose registers (default with no args) or
dump area of memory to output file.
*********
Chapter 7. Interactive Debug Facility
*********
A. Overview
The PC/370 interactive debug facility is designed to provide a
tool to help debug program errors in either 80x86 code or 370
code. The facility provides the basic tools namely tracing
program flow via breakpoints defined by calls, and displaying
register and memory contents upon request. In addition, the
facility provides a data and address stop option which is very
useful for locating errors.
B. Program Interface
The PC/370 interactive debug facility is implemented via a single
module named MMDBUG which is linked into A370, L370 and E370
programs and is called with a single 3 byte ASCII argument
located immediately after the near call instruction. In the
E370 emulator environment, the interactive debugger can be called
directly from 370 programs through SVC 9 which must be followed
by 3 byte EBCDIC argument and a 1 byte filler to keep
instructions on half word boundary.
There are several special calling arguments as follows:
1. 'OFF' - turn off (kill) trace facility for speed
(a trace is killed by replacing call with jump over
the trace ID to the next instruction)
2. 'ON ' - turn trace facility back on (stop killing traces)
3. 'BUG' - force interactive debug mode
4. 'IOF' - interrupts off (unsolicited keys queued for input)
5. 'ION' - interrupts on (any key stroke invokes user
interface)
6. 'IFL' - instruction fetch loop (special trace used in E370
to identify next trace id as 370 operation trace to
be stored in trace table)
The first call to MMDBUG in A370, L370, and E370 is with 'OFF'
unless the trace option was requested via COM file parm or if the
debug option D was specified on link edit of COM or BIN file.
C. User Interface
When MMDBUG is called without the 'OFF' argument, or when a key
is hit without the 'IOF' argument being issued previously, the
user interface mode is invoked and the following commands may
be entered in upper or lower case from the console:
A - ADDRESS STOP (PROMPTS FOR ADDRESS, LENGTH, TYPE)
C - CONTINUE TO NEXT TRACE ENTRY
D - DUMP MEMORY (PROMPTS FOR ADDRESS)
F - FIND TRACE ENTRY (PROMPTS FOR TRACE ID)
H - HELP LIST MMDBUG COMMANDS (THIS LIST)
I - INSTRUCTION COUNTER WORD
J - RESET NEXT 370 OR 8086 INSTRUCTION ADDRESS
K - KILL MODE SET/RESET (kills or restores traces)
L - SET/RESET TRACE LIMIT FOR Q/T MODE
M - MODIFY MEMORY (PROMPTS FOR ADDRESS AND DATA)
N - LIST LAST 20 TRACE ENTRIES (NOTE K,Z AFFECT THIS LIST)
P - SET/RESET PRINT COPY OF ALL MMDBUG I/O
Q - SET QUIET MODE (USED WITH F, L, AND 'BUG' OPTIONS)
R - DISPLAY REGISTERS (SEE Z OPTION)
S - SAVE/UNSAVE CURRENT TRACE ID FROM KILL MODE
T - SET TRACE MODE (USED WITH OPTIONS F AND L)
W - LIST FREE MEMORY QUEUE
X - SET/RESET ASSIST LOGGING OF INTERACTIVE DEBUG OUTPUT
Y - MODIFY 8086/370 REGISTER (PROMPTS FOR REGISTER/DATA)
Z - SET/RESET 8086/370 MODE
IN 8086 MODE, R DUMPS 8086 REGISTERS AND D PRINTS
PRINTABLE ASCII CHARACTERS IN DUMP.
IN PC/370 MODE, R DUMPS 370 REGISTERS AND PSW
AND D DUMPS PRINTABLE EBCDIC CHARACTERS IN DUMP.
<cr> - dump same address again as defined in D command
<sp> - dump forward until any key hit
<bs> - dump backwards until any key hit
<esc>- exit to MSDOS after attempting to close files
Memory addresses may be entered in xxxx:xxxx or xxxxxx hex format
without leading zeros required. In 370 mode, the xxxxxx format
always refers to the relative address within the current address
space. In 80x86 mode, the xxxxxx format refers to the offset
using the current segment. The segment:offset is initialized to
the emulator data segment area containing the 370 registers.
D. User Guide
The PC/370 interactive debug facility can assist you in locating
errors within your 370 assembler programs. But first there are
some more basic things to check:
1. Are you sure that you are executing the latest version of
the source program. To be absolutely sure, code the date
and time in a print statement at the beginning of the program
and then reassemble (A370) and relink (L370) and execute the
program again.
2. Does the program run to normal termination? If so then you
can run the program again specifying a T as the only parameter
on the execute command to initiate the interactive debug
facility. Another way to invoke the interactive debug option
is to specify option D in the linkage editor. This method
should be used if the program requires a parameter other than
T.
3. If the program terminated abnormally, the interactive debug
facility is automatically initiated along with a display of
the PSW and the failing instruction. To calculate the
relative address of the failing instruction in the program,
subtract the program load address of X'0200' (Note you will
have to look at the link edit listing to get the starting
address if the failing instruction is in a subroutine.
4. To trace execution of the program, enter K once or twice to
restore all traces and then enter T. To stop the trace at any
point hit any key.
5. To continue execution of the program normally, enter Q.
For fast execution, use K command to set kill trace mode
first.
6. To dump the current contents of the registers, enter R.
7. To dump any 32 byte area in memory, enter A followed by
the starting address in hex xxxx.
8. To continue to dump memory from the current location forward,
hit the space key. To dump backwards, hit the backspace key.
To stop the dump, hit any key.
9. To stop the program at a specific address, enter A followed
by the address in hex xxxx followed by the option code A.
Then use Q or T to continue execution until the address is
found.
10. To stop the program when a specific data field in memory is
changed, enter A followed by the address in xxxx followed by
the option code E for equal data or N for not-equal data.
Next entry the length of the data compare in hex when
prompted. If option E is selected, enter the hex value of the
data you want to search for when prompted. Next press Q or T
to continue execution until the data compare specified
triggers debug user interface again. To stop at a specific
instruction count in a 370 program, use the I command to
display the instruction counter word and then use data equal
address stop on the word. To obtain detail instruction trace
up to point of failure, either use Q or T from beginning of
the program or set address stop at previous multiple of 256
on instruction count field and then restore traces with K
command and then use Q or T proceed to point of failure. At
point of failure, use N command to list last 20 instruction
trace points.
11. To turn off any address stop option, enter A.
12. To list the last 20 instruction trace table entries, enter N.
If running in 370 mode (option Z toggles mode), only the 370
instruction traces will be stored and listed via option N.
In 80x86 mode, all traces will be stored and listed.
Note that this list may be incomplete if the program
was running with K option active to kill traces for speed.
Option K kills each trace entry to debug the first time debug
is entered for that trace point. Option K makes the program
run much faster at the expense of losing repeated trace
points until K reset is issued. However, you can use Find to
locate selected trace id's and use Save to protect id from
kill mode. This option allows much faster execution while
still being able to trace selected id's. A very useful id to
save is IFL which will then trace each 370 instruction during
kill mode while killing all of the lower level ID's for
reasonable speed yet full visibility of 370 instructions.
Faster still is to save only one 370 instruction id such as
TRT. This is very useful in conjunction with address stop,
since the address stop overhead is only incurred for the
selected saved id's. Note that the trace table only contains
addresses of instructions, and as a result if instruction
modification or overlays are used, the data listed for a
previous instruction may be different from what it was at the
time it was executed. In this case it may be helpful to rerun
program with address stop to see what was in memory at the
time an instruction was executed.
13. To set a fixed limit on the number of trace entries before
entering debug command mode again, enter L and count in hex
xxxx. Next enter Q or T to continue until count reached zero.
If zero count is entered, the limit is not checked.
14. To modify memory, enter M followed by address in hex xxxx.
Next enter hex data bytes followed by return key.
15. To display the 8086 registers, type Z to switch to 8086 mode.
Now type R. In 8086 mode, storage dumps translate data to
ASCII instead of EBCDIC for character display. In 8086 mode,
N lists all trace entries instead of just IFL 370 instruction
traces. In 8086 mode, Y changes 8086 registers instead of 370
registers. To return to 370 mode, type Z again.
16. The W command displays free memory in the 8086 data segment
for 8086 mode and the free memory in the current address
space in 370 mode. Note these are two totally separate free
areas. The 8086 free area is limited to <= 64k addressable by
the DS register and uses 4 byte free queue elements
(next,length). The 370 free area extends from the end of 370
code in COM module to the end of free memory and uses 8 byte
370 format free queue elements (next,length) on 8 byte
boundaries. For BIN file execution, the free area is the SQA
area allocated in the emulator address space. The first free
queue element in a 370 address space is pointed to by ASCASF
field in address space control block located at X'104' in low
memory (may be zero if no free memory currently available).
The ASCB for BIN modules can be located by subtracting
(X'200'-X'104') from the entry point address in register 15 at
entry (trace ID 370).
17. The J jump command may be used to modify either the emulator
or the 370 current instruction address depending on the
current Z mode. In 370 mode, the address entered is a virtual
address. In 80x86 mode, the address entered is a code segment
offset (This is a very dangerous function and not
recommended).
*********
Chapter 8. Floating Point Support
*********
A. Register formats
1. General purpose registers
The general purpose 370 registers are located at the beginning
of the data segment of the E370 emulator (DS:0). They are
stored in 80x86/80x87 long integer format with least
significant byte first starting with register 0. For example,
the high byte of register 0 is at DS:3 and the low byte of
register 1 is at DS:4. This area can be used with address
stop to detect a specific register value or change in register
value (although remembering reverse format is always a
challenge). This format is used to allow native loads and
stores without reversing bytes which speeds up register to
register operations and allows addition of registers directly
from memory without conversion.
2. Floating point registers
If the 80x87 co-processor is installed, the R command displays
the four 8 byte floating point register values numbered 0, 2,
4, and 6. This is one way (other than 123 /WS screen) to tell
if 80x87 is installed. The floating point registers are
stored in 80x87 temporary real format which is 10 bytes long.
The first 8 bytes contain the normalized 64 bit unsigned
mantissa with the high bit always on stored in reverse order
(like a double long integer with the least significant byte at
low address. The last 2 bytes contain the base two exponent
and the sign stored as an integer. The 15 bit exponent is
stored in excess 3FFFH format. True zero is represented by
plus or minus sign and all other bits zero. This format
exceeds 370 double precision 8 byte format for both mantissa
and exponent range. This format is used to significantly
speed up floating point register to register operations since
numbers can be directly transferred to/from 80x87 in this
format. A conversion routine must be used to convert floating
point numbers when moved to/from memory to the floating point
registers. The conversion routine is quite efficient but does
involve shifting entire number up to 3 bits left or right to
convert from normalized base 2 to base 16. The floating point
register memory area can be dumped to see the real format and
can be used with address stop to detect specific value or
change in value.
B. Floating Point Scientific Subroutine Package
Using floating point 370 instructions plus extended 80x87 function
SVC's described in SYSTEM.DOC, a set of efficient scientific
subroutines have been coded in SSP.ALC and are stored in the
L370.LIB subroutine library. The argument and result is in F0 or
R0 unless noted otherwise. The SSP functions are similar to the
FORTRAN IV intrinsic functions.
FUNCTION DESCRIPTION RANGE LIMITATIONS NOTES
ATAN ARCTAN
ALOG LOG BASE E 0 < F0
ALOG10 LOG BASE 10 0 < F0
COS COSINE
EXP E ** X
REAL CVT TO REAL -2**32 <= R0 < 2**32 ARG. IN R0
INT CVT TO INT -2**32 <= F0 < 2**32 RESULT IN R0
MOD MOD(F0,F2) REMAINDER R0
PI PI 3.14159.............
SIN SINE
SQRT SQUARE ROOT 0 <= F0
TAN TANGENT
C. Floating point co-processor assisted standard 370 instructions.
1. If the floating point option is on and an 80x87 co-processor
is installed, then it is used to assist the CVB and CVD
instructions for speed. In the case of large numbers, the
speed improvement can be up to 4 times. For numbers close
to zero, there is no improvement in speed. Depending on
user demand, this type assist may be added for other packed
decimal instructions in the future.
*********
Chapter 9. XA Extended Architecture Support
*********
1. A370 supports the XA instructions as defined in the
IBM System/370 XA Principles of Operation manual version
SA22-7085.
2. E370 supports the 6 XA non-privileged instructions
BAS, BASR, MVCIN, BASSM, IPM, and BSM. When the emulator is in
31 bit mode, the PSW format displayed by MMDBUG is extended mode
with the high address bit on. The emulator defaults to 24 bit
mode and the 370 basic PSW format.
3. The standard instructions LA, BAL, BALR, EDMK, and TRT
now support both the 24 bit and 31 bit addressing modes
as set by BASSM or BSM using the PSW address mode bit.
Note that in 31 bit addressing mode the LA instruction
adds all 31 bits of the index and base register plus
displacement and clears only the high bit of the result. This
means the high byte of the index and base must be cleared when
using 24 bit addresses in 31 bit mode.
**********
Chapter 10. System subroutine library
**********
The following subroutines are included in the default system
subroutine relocatable library L370.LIB in the root directory:
# SUBROUTINE ENTRY FUNCTION ARGUMENTS
1 DAT print date and time none
2 TIMER return current time none
of day in R0 in 100th
of a second units
3 PET print elapsed time since none
last call plus date and
time and 370 instruction
count interval statistics
4 DTIME print time in upper left none
corner of screen in format
HH:MM:SS
5 SYNERROR print PC/370 input/output R0 = error code
error message based on R1 = function code
return codes passed in
registers R0-R1 at entry
to SYNAD DCB exit routine
6 SSP scientific subroutines
(see chapter 8 for entry
points to this module)
7 API support application using
application program interface
(API) with IBM PC 3270
emulation via interrupt 7A
The 370 source code for all of the above modules is in the LIB
directory, and the BAT\BLDLIB.BAT command file will rebuild library
from the source. Remember when adding subroutines to a relocatable
library that there cannot be any backward references to prior modules
in the library since L370.EXE uses serial one pass search for external
references in the library.
**********
Chapter 11. COBOL call interface support
**********
To call a PC/370 assembler subroutine from a Micro Focus COBOL program
requires that the PC/370 emulator E370R42.EXE be made resident by
executing it directly (see BAT\RUNCBL.BAT for demo). Each subroutine
to be called must be assembled and linked using option B to create a
BIN type file which will be dynamically loaded on the first call.
The interface performs the following functions prior to transferring
control to the assembler subroutine:
1. The address space control block at X'104' in the BIN file is
initialized to a virtual equals real (V=R) region in order to
address the arguments passed. The ASCASF free memory pointer
is initialized to point to the current first free queue element
in the common system queue area (SQA) memory allocated along
with the resident emulator. The SQA is used to dynamically
allocate buffers for subroutine file I/O and any other dynamic
memory requests via GETMAIN/FREEMAIN svc's. Note that SQA is
shared by all subroutines and each subroutine must release any
memory it uses prior to exit or SQA will eventually be depleted
(just like MVS).
2. The segment and offset argument addresses on the stack are
converted into a standard 370 calling list of 32 bit absolute
addresses located at X'80' in the BIN file (normally the command
line area). Up to 32 arguments can be passed.
3. The 370 registers are set as follows:
R1 = absolute address of argument list at X'80' in BIN file
R14 = absolute return address to exit subroutine at X'102' in
BIN file via detach SVC.
R15 = absolute address of entry point (normally X'210' in BIN
file. At exit from called BIN module, the low 16 bits of
register 15 are used to set special Micro Focus COBOL return
code value called RETURN-CODE. If emulator is not resident
when a BIN module is called, a return code of 16 is passed.
4. If option D was specified in the L370 link of the BIN module
being called, the emulator interactive debug facility will be
invoked at entry with all traces restored. If option D was
not specified, execution will proceed without interruption and
no traces will be restored to provide fast execution of one or
more BIN modules.
5. Note that BIN modules are dynamically loaded by COBOL run time
system at unknown addresses. Since BIN subroutines run in
V=R address mode in order to address COBOL data areas, all 370
subroutine code must be self relocating. See CBL\TESTCIO.ALC
for example of how to relocate any address constants required
such as subroutine entry points and DCB addresses. The A370
assembler lists all relocation addresses in PRN listing created
with the /L option.
**********
Chapter 12. Technical References:
**********
1. For information on 370 machine instructions see
IBM System 370 XA Principles of Operation manual SA22-7085.
2. For information on 370 assembler language see:
a. IBM OS/VS Assembler Language manual GC33-4010.
b. Assembler Language Programming by G. W. Struble.
3. For information on how the assembler, linkage editor, and
operating system software works see:
a. Systems Programming by John J. Donovan.
b. Operating Systems by S. E. Madnick and J. J. Donovan.
4. For information on the 80x86 processors see:
a. The 8086 Book by George Alexy.
b. Intel iAPX 286 Programmer's Reference Manual 210498-003.
c. Intel 80386 Programmer's Reference Manual 230985-001.
5. For information on the MSDOS operating system and utilities
see:
a. Disk Operating System Version 3.2 Reference 68X2405.
b. Disk Operating System Technical Reference 6139658.
c. Advanced MS-DOS by Microsoft Press ISBN 0-914845-77-2
6. For information on usage of ASSIST extensions see:
a. Assembler Language with Assist by Ross A. Overbeek and W.
E. Singletary. Published by Science Research Associates,
Inc., Chicago, Copyright 1976, ISBN 0-574-21085-7.
b. IBM 370 Assembly Language with ASSIST, Structured Concepts,
and Advanced Topics by Charles J. Kacmar. Published by
Prentice Hall, September 1987, ISBN 0-13-455742-5.
7. For summary article on how PC/370 was developed see ACM
Sigsmall Newsletter Volume 8 Number 3, August 1982.
8. For article on conversion of PC/370 from CP/M to MS-DOS see
ACM SIGSMALL/PC Newsletter Volume 11 Number 3, August 1985.
9. For information on 80x87 see Intel iAPX 286 Programmer's
Reference Manual #210498-003. Also book by designer titled,
"The 8087 Primer" by John F. Palmer and Stephen P. Morse,
published by John Wiley & Sons, inc. Copyright 1984, ISBN 0-
471-87569-4.